Journal
JOURNAL OF STRUCTURAL ENGINEERING-ASCE
Volume 134, Issue 4, Pages 581-592Publisher
ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)0733-9445(2008)134:4(581)
Keywords
-
Ask authors/readers for more resources
This paper investigates the consequence of using Rayleigh proportional damping in the analysis of inelastic structural systems. The discussion is presented theoretically, as well as by example through the analysis of a simple five-story structure. It is shown that when the stiffness portion of the system damping matrix is based on the original system stiffness, artificial damping is generated when the structure yields. When the damping matrix is based on the tangent stiffness but the Rayleigh proportionality constants are based on the initial stiffness, a significant but reduced amplification of damping occurs. When the damping is based on the tangent stiffness and on updated frequencies based on this stiffness, virtually no artificial damping occurs. The paper also investigates the influence on effective damping when localized yielding occurs in areas of concentrated inelasticity. In such cases, it is possible to develop artificial Viscous damping forces that are extremely high, but that are not easy to detect. Such artificial damping forces may lead to completely invalid analysis. The paper ends with recommendations for performing analysis where the artificial damping is eliminated, or at least controlled.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available