4.3 Article

Reconstruction of the coronoid using an extended prosthesis: an in vitro biomechanical study

Journal

JOURNAL OF SHOULDER AND ELBOW SURGERY
Volume 21, Issue 7, Pages 969-976

Publisher

MOSBY-ELSEVIER
DOI: 10.1016/j.jse.2011.04.014

Keywords

Coronoid; elbow; biomechanics; fracture; type II; instability; replacement

Funding

  1. Canadian Institute of Health Research
  2. Physician's Services Incorporated Foundation

Ask authors/readers for more resources

Background: When repair of comminuted coronoid fractures is not possible, prosthetic replacement may restore elbow stability. The purpose of this biomechanical study was to determine whether a coronoid implant with an extended tip would improve elbow stability compared with an anatomic prosthesis in the setting of collateral ligament insufficiency. Materials and methods: Passive elbow extension was performed in 7 cadaveric arms in the varus and valgus positions and active and passive extension in the horizontal position by use of an elbow motion simulator. Varus-valgus laxity of the ulna relative to the humerus was quantified with a tracking system with a native coronoid, a 40% coronoid deficiency, an anatomic prosthesis, and an extended prosthesis, with the collateral ligaments sectioned and repaired. Results: Laxity significantly increased after a 40% coronoid deficiency with both repaired and sectioned collateral ligaments (P <= .01). With the ligaments repaired, there was no significant difference in laxity between the native coronoid, the anatomic implant, or the extended implant. Ligament sectioning alone produced severe instability, with a mean laxity of 42.75 degrees +/- 11.54 degrees (P < .01). With insufficient ligaments, the anatomic prosthesis produced no change in laxity compared with the native coronoid, whereas the extended implant significantly reduced laxity by 21.56 degrees +/- 17.70 degrees (P = .02). Conclusions: An anatomic coronoid implant with ligament repair restores stability to the coronoid-deficient elbow to intact levels. In the setting of ligament insufficiency, an extended implant improves stability relative to an anatomic implant, but the elbow remains significantly less stable than an intact elbow. Studies are needed to evaluate the feasibility of these designs. Level of evidence: Basic Science Study, Biomechanical Study. (C) 2012 Journal of Shoulder and Elbow Surgery Board of Trustees.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available