Optimizing Performance of Glycopeptide Capture for Plasma Proteomics

Journal

JOURNAL OF PROTEOME RESEARCH
Volume 9, Issue 4, Pages 1706-1715

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/pr900845m

Keywords

solid phase extraction of N-linked glycoproteins; proteomics; glycoproteins; hydrazide chemistry; biomarker discovery; glycopeptide

Funding

  1. Bill and Melinda Gates Foundation
  2. National Institutes of Health [1U24 CA126476]
  3. NCI's Clinical Proteomic Technologies Assessment in Cancer Program
  4. National Heart Lung and Blood Institute [R01 HL096738-01]
  5. Women's Cancer Research Fund of the Entertainment Industry Foundation
  6. Western Norway Regional Health Authority
  7. Norwegian Research Council

Ask authors/readers for more resources

Selective capture of glycopolypeptides followed by release and analysis of the former glycosylation-site peptides has been shown to have promise for reducing the complexity of body fluids such as blood for biomarker discovery. In this work, a protocol based on capture of polypeptides containing a N-linked carbohydrate from human plasma using commercially available magnetic beads coupled with hydrazide chemistry was optimized and partially automated through the use of a KingFisher magnetic particle processor. Comparison of bead-based glycocapture at the protein-level vs the peptide-level revealed differences in the specificity, reproducibility, and absolute number of former glycosylation-site peptides detected. Evaluation of a range of capture and elution conditions led to an optimized protocol with a 24% intraday and 30% interday CV and a glycopeptide capture specificity of 99%. Depleting the plasma of 14 high abundance proteins improved detection sensitivity by approximately 1 order of magnitude compared to nondepleted plasma and resulted in an increase of 24% in the number of identified glycoproteins. The sensitivity of SPEG for detection of glycoproteins in depleted, non-fractionated plasma was found to be in the 10-100 pmol/mL range corresponding to glycoprotein levels ranging from 100's of nanograms/mL to 10's of micrograms/mL. Despite high capture specificity, the total number of glycoproteins detected and the sensitivity of SPEG in plasma is surprisingly limited.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available