4.5 Article

THE EFFECT OF EQUILIBRATING MOUNTED DENTAL STONE CASTS ON THE OCCLUSAL HARMONY OF CAST METAL COMPLETE CROWNS

Journal

JOURNAL OF PROSTHETIC DENTISTRY
Volume 104, Issue 2, Pages 122-132

Publisher

MOSBY-ELSEVIER
DOI: 10.1016/S0022-3913(10)60105-9

Keywords

-

Funding

  1. Baylor College of Dentistry

Ask authors/readers for more resources

Statement of problem. Fabrication of indirect complete crowns that are in occlusal harmony upon insertion remains a problem in restorative dentistry, and dental stone cast expansion may play a role. Purpose. This 3-part investigation compared occlusal contacts in a simulated patient with a harmonious occlusion with centric occlusion equal to maximum intercuspation (CO=MI) and an inharmonious occlusion (CO not equal MI) with mounted stone casts, and compared the occlusal contacts after fabrication of a postertor complete crown fabricated on equilibrated and nonequilibrated dental stone casts. Material and methods. A dentoform mounted in a semi-adjustable articulator served as the simulated patient and control. In part 1, a single set of maxillary and mandibular ADA type IV and V derived dental stone casts were fabricated and mounted (CO not equal MI), and occlusal contacts/near contacts were compared In part 2, 10 type IV and 10 type V cast mountings (CO=MI) were compared In part 3, 10 type IV cast mountings were fabricated for adjustment (experimental) and 10 for no adjustment (control). A mandibular ADA type IV gold alloy complete crown was fabricated and adjusted on each set of casts and then returned to the dentoform Vinyl polysiloxane interocclusal records of all mountings were scanned for optical density, and contacts were used to quantify occlusal contacts as exhibiting contact or near contact. Data were analyzed with Kruskal-Wallis ANOVA and Mann-Whitney U tests (alpha=05). Results. The cast adjustment protocol (intervention) was successful in eliminating the majority of the occlusal disharmony in the casts believed to be caused by the effects of stone expansion. Actual and near contact areas for cast mountings of the equilibrated simulated patient were significantly different from those of the simulated patient (P<.001, P=001, respectively). Actual and near contact areas for inserted crowns fabricated from adjusted casts were significantly different from those of the simulated patient (P<001; P=.007, respectively), but actual contact areas were not different from those of the simulated patient with no crown inserted Conclusions. In this study, occlusal contacts of a simulated patient (dentoform) could not be accurately replicated with mounted dental stone casts A cast adjustment procedure can aid in fabrication of a crown with a more accurate occlusion Prosthet Dent 2010;104 122-132)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available