4.6 Article

Ti/TiO2 Nanotube Array/Ni Composite Electrodes for Nonenzymatic Amperometric Glucose Sensing

Journal

JOURNAL OF PHYSICAL CHEMISTRY C
Volume 114, Issue 10, Pages 4408-4413

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/jp912232p

Keywords

-

Funding

  1. National Nature Science Foundation of China [50872071, 50972079]
  2. Shandong Natural Science Fund [JQ200915]
  3. Nature Science Foundation of Shandong Province [Y2007F03, Y2008F26]
  4. Foundation of Outstanding Young Scientists in Shandong Province [2006BS04030]
  5. Tai Shan Scholar Foundation of Shandong Province
  6. Gong Guan Foundation of Shandong Province [2008GG10003019]

Ask authors/readers for more resources

TiO2 nantube arrays (NTAs) with a tube diameter of about 100 nm were prepared by anodic oxidation, and a Ni layer about several tells of micrometers thick was electrodeposited oil the Surface of TiO2 NTAs. The synthesized Ti/TiO2 NTA/Ni composite electrodes were used for nonenzymatic glucose detection. The behavior of the anodic TiO2 NTA/substrate Ti metal is analogous to characteristics of an n-type semiconductor/metal Schottky barrier diode. The characteristic Would enhance the rapid transport of surface reaction electrons to the metal substrate, thereby enhancing the performance of biosensors. Cyclic voltammogram investigations indicate that calcined Ti/TiO2 NTAs have a wider work potential window than that of Ti/TiO2 NTAs without calcinations and Ti foils. Moreover, the low saturated current in alkaline Solutions Under a constant potential makes Ti/TiO2 NTAs Favorable as substrate materials for biosensors. For the Ti/TiO2 NTA/Ni composite electrodes, the relationship between the linear range and the potential was investigated. The positive line scans and the amperometric response curves to glucose indicated that I potential of 0.5-0.6 V Would be Favorable to get a wide linear range for detecting glucose. The sensitivity of the composite electrodes call reach a Value as high as 200 mu A mM(-1) cm(-2), and the detection limit wits about 4 PM with it signal-to-noise ratio of 3 (S/N = 3). The present Ti/TiO2 NTA/Ni composite flonenzymatic amperometric glucose sensor Could find potential applications in a good biosensing platform for other redox proteins and enzymes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available