4.6 Article

Experimentation and Theoretic Calculation of a BODIPY Sensor Based on Photoinduced Electron Transfer for Ions Detection

Journal

JOURNAL OF PHYSICAL CHEMISTRY A
Volume 113, Issue 51, Pages 14081-14086

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/jp907331q

Keywords

-

Funding

  1. National Basic Research Program of China [2006CB806104, 2007CB925103]
  2. NSFC [20971066, 20875043, 20873058]

Ask authors/readers for more resources

A boron-dipyrromethene (BODIPY)-based fluorescence probe with a N,N'-(pyridine-2, 6-diylbis(methylene))-dianiline substituent (1) has been prepared by condensation of 2,6-pyridinedicarboxaldehyde with 8-(4-amino)4,4-difluoro-1,3,5,7-tetramethyl-4-bora-3a,4a-diaza-s-indacene and reduction by NaBH4. The sensing properties Of compound 1 toward various metal ions are investigated via fluorometric titration in methanol, which show highly selective fluorescent turn-on response in the presence of Hg2+ over the other metal ions, such as Li+, Na+, K+, Ca2+, Mg2+, Pb2+, Fe2+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+, Ag+, and Mn2+. Computational approach has been carried out to investigate the mechanism why compound 1 provides different fluorescent signal for Hg2+ and other ions. Theoretic calculations of the energy levels show that the quenching of the bright green fluorescence of boradiazaindacene fluorophore is due to the reductive photoinduced electron transfer (PET) from the aniline subunit to the excited state of BODIPY fluorophore. In metal complexes, the frontier molecular orbital energy levels changes greatly. Binding Zn2+ or Cd2+ ion leads to significant decreasing of both the HOMO and LUMO energy levels of the receptor, thus inhibit the reductive PET process, whereas an oxidative PET from the excited state fluorophore to the receptor occurs, vice versa, which also quenches the fluorescence. However, for 1-Hg2+ complex, both the reductive and oxidative PETs are prohibited; therefore, strong fluorescence emission from the fluorophore can be observed experimentally. The agreement of he experimental results and theoretic calculations Suggests that Our calculation method can be applicable as guidance for the design of new chemosensors for other metal ions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available