In this study, a fast, simple and efficient method based on ultrasound-assisted emulsification-.microextraction (USAEME) coupled with ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was successfully developed for the determination of ibuprofen (IBU) and its four metabolites (1-hydroxyibuprofen (1-HIBU), 2-hydroxyibuprofen (2-HIBU), 3-hydroxyibuprofen (3-HIBU), carboxyibuprofen (CIBU)) in human urine. For this purpose, the influence of the different parameters affecting the USAEME procedure was evaluated in order to optimize the efficiency of the process. The optimum conditions were found to be: 100 mu L of 1-octanol as extraction solvent, 2 mL of urine sample, 15% (w/v) NaCl to control the ionic strength, ultrasonication for 10 min; and centrifugation for 5 min at 6500 rpm. After sample preparation, chromatographic separation was achieved on a Zorbax Rapid Resolution High Definition (RRHD) SB-C18 column using the mobile phase consisting of 0.1% formic acid in water and acetonitrile in an elution gradient. Detection was performed in a triple quadrupole tandem mass spectrometer using the multiple reaction monitoring (MRM) mode and negative ionization. The proposed method showed satisfactory linearity over a wide concentration range (correlation coefficients over 0.9994). The lower limit of quantification (LLOQ) was 0.0005 ng/mL for IBU and its metabolites. The intra- and inter-day precisions were in the range of 2.19-10.8% and the accuracies were between -5.93% and 6.29%. The mean recovery of analytes ranged from 90.7 to 104%. As a result, this method has been successfully applied for the sensitive determination of IBU and its metabolites in human urine samples. (C) 2014 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available