4.6 Article

Determination of anabolic steroids in human urine by automated in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry

Journal

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume 52, Issue 5, Pages 727-733

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpba.2010.02.027

Keywords

In-tube solid-phase microextraction; Automated sample preparation; Anabolic steroids; Doping control; Liquid chromatography-mass spectrometry

Funding

  1. Grant-in-Aid for Basic Scientific Research [19590049]
  2. Grant-in-Aid for Exploratory Research [16659014]
  3. Grants-in-Aid for Scientific Research [16659014, 19590049] Funding Source: KAKEN

Ask authors/readers for more resources

A simple, rapid and sensitive method was developed for determining the presence of seven anabolic steroids (boldenone, nandrolone, testosterone, methyltestosterone, epiandrosterone, androsterone, and atnozolol) in human urine Glucuronide-conjugates of these compounds were hydrolyzed with beta-glucuionidase The anabolic steroids were analyzed by on-line in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-mass spectrometry (LC-MS) The steroids wet e separated within 14 min by high performance liquid chromatography using a Chromolith RP-18e column and 5 mM ammonium for mate/methanol (35/65, v/v) as a mobile phase at a flow rate of 1 0 mL/min Electrospray ionization conditions in the positive ion mode were optimized for the MS detection of these compounds The optimum in-tube SPME conditions were 20 draw/eject cycles with a sample size of 40 mu L. using a Supel-Q PLOT capillary column RA the extraction The extracted compounds could be desorbed readily from the capillary column by flow of the mobile phase, and no carryover was observed. Using the in-tube SPME LC-MS with SIM mode detection, good linearity of the calibration curve (r > 0 995) was obtained in the concentration range of 0 5-20 ng/mL, except for stanozolol The detection limits (S/N = 3) of anabolic steroids were in the range 9-182 pg/mL and the proposed method showed 20-33-fold higher sensitivity than the direct injection method The within-day and between-day precisions were below 4 0% and 7 3% (n =5), respectively This method was applied successfully to the analysis of urine samples without the interference peaks The recovery rates of anabolic steroids spiked into urine samples wet e above 85% This method is useful to analyze the urinary levels of these compounds in anti-doping tests. (C) 2010 Elsevier B V All tights reserved

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available