4.5 Article

Entropy analysis of tri-axial leg acceleration signal waveforms for measurement of decrease of physiological variability in human gait

Journal

JOURNAL OF ORTHOPAEDIC RESEARCH
Volume 30, Issue 6, Pages 897-904

Publisher

WILEY
DOI: 10.1002/jor.22022

Keywords

gait analysis; physiological variability; inertial monitor; sample entropy; knee osteoarthritis; complexity

Categories

Funding

  1. Foundation for Physical Medicine and Rehabilitation
  2. NIH-NIAMS Centers of Research Translation [P50-AR055533]
  3. NIH-NIA [K23-AG030945]

Ask authors/readers for more resources

Disease-related and senescent decrease of physiological variability in biological time-series outputs (e.g., heart rate) has drawn increasing attention as a potential new type of biomarker. In this paradigm, measurement of variability in periodic motion may enable quantitative evaluation of functional limitation in people with musculoskeletal disorders. A novel technique to measure variability of leg motion patterns during level walking was used to study 52 adults with symptomatic knee osteoarthritis (OA), and 57 asymptomatic control subjects over a wide range of age (2079 years). The hypothesis was that cycle-to-cycle variability in leg motion patterns, indexed by tri-axial acceleration signal entropy, would be lower in those with greater age or with knee symptoms. Leg motions were assessed using portable inertial monitors attached bilaterally just above each ankle. The tri-axial acceleration data were analyzed using a nonlinear variability measurement tool designated as Sample Entropy (SampEn). SampEn data for asymptomatic subjects exhibited a significant negative correlation (r?=?-0.287, p?=?0.0306) with greater age. OA subjects had significantly lower SampEn values (p?=?0.0002) than did age-matched asymptomatic subjects who walked at equivalent velocity. This approach holds promise as a basis for valid, inexpensive, and convenient objective evaluation of limitations in human gait function. (c) 2011 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:897904, 2012

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available