4.4 Article

Engineering patient-specific drill templates and bioabsorbable posterior cervical plates: a feasibility study Technical note

Journal

JOURNAL OF NEUROSURGERY-SPINE
Volume 10, Issue 2, Pages 129-132

Publisher

AMER ASSOC NEUROLOGICAL SURGEONS
DOI: 10.3171/2008.11.SPI0817677

Keywords

bioabsorbable instrumentation; computer template; spine surgery

Ask authors/readers for more resources

Object. The authors describe a method of using computer models to generate Customized cervical implants. A promising yet challenging technique in cervical spine surgery involves the use of pedicle screws to assist with posterior instrumentation. Surrounding anatomical structures Such as the vertebral arteries and cervical nerve roots present challenges for safe screw placements however. the use of computer-generated templates seems to be a promising method to assist with placement. In this study, the authors explore the use of computer-generated templates and introduce their methods for creating custom, bioabsorbable posterior cervical implants. Methods. The cervical spines (C2-T1) from 4 cadavers were scanned with volumetric CT. Using commercially available software, the authors generated volumetric models of a cervical drill template and the mold for a cervical plate spanning a desired number of vertebrae. The computer generated models of the cervical drill template and cervical plate mold were converted into physical models using a rapid prototyping machine. The biopolymer polylactic acid resin was heated to 250 degrees C and resolidified to form thin similar to 5-min-thick plates. The newly formed plates were reheated to 60 degrees C and cast on the cervical mold. Results. The resulting translucent plates were found on Visual inspection to have it secure lock-and-key fit on the original cadaver spine, and the techniques used were robust and reproducible. The process described ill this brief report provides the background to proceed with development and testing of these patient-absorbable templates. Conclusions. The creation and use of patient-specific bioabsorbable posterior cervical plates in conjunction with multilevel drill templates appear promising. Additional feasibility Studies are planned. and in vitro studies are required to determine the safety and efficacy of using patient-specific drill templates and converting them into bioabsorbable implants. (DOI: 10.3171/2008.11.SPI0817677)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available