4.4 Article

Assessment of the impact of photosystem I chlorophyll fluorescence on the pulse-amplitude modulated quenching analysis in leaves of Arabidopsis thaliana

Journal

PHOTOSYNTHESIS RESEARCH
Volume 125, Issue 1-2, Pages 179-189

Publisher

SPRINGER
DOI: 10.1007/s11120-015-0087-z

Keywords

Arabidopsis; Protective NPQ; Photoinhibition; Photosystem II; Photosystem I

Categories

Funding

  1. UK Biotechnology and Biological Sciences Research Council
  2. Leverhulme Trust
  3. Queen Mary Principal's research studentship
  4. Biotechnology and Biological Sciences Research Council [BB/L019027/1] Funding Source: researchfish
  5. BBSRC [BB/L019027/1] Funding Source: UKRI

Ask authors/readers for more resources

In their natural environment, plants are exposed to varying light conditions, which can lead to a build-up of excitation energy in photosystem (PS) II. Non-photochemical quenching (NPQ) is the primary defence mechanism employed to dissipate this excess energy. Recently, we developed a fluorescence-quenching analysis procedure that enables the protective effectiveness of NPQ in intact Arabidopsis leaves to be determined. However, pulse-amplitude modulation measurements do not currently allow distinguishing between PSII and PSI fluorescence levels. Failure to account for PSI contribution is suggested to lead to inaccurate measurements of NPQ and, particularly, maximum PSII yield (F (v)/F (m)). Recently, Pfundel et al. (Photosynth Res 114:189-206, 2013) proposed a method that takes into account PSI contribution in the measurements of F (o) fluorescence level. However, when PSI contribution was assumed to be constant throughout the induction of NPQ, we observed lower values of the measured minimum fluorescence level () than those calculated according to the formula of Oxborough and Baker (Photosynth Res 54:135-142 1997) (), regardless of the light intensity. Therefore, in this work, we propose a refined model to correct for the presence of PSI fluorescence, which takes into account the previously observed NPQ in PSI. This method efficiently resolves the discrepancies between measured and calculated F (o') produced by assuming a constant PSI fluorescence contribution, whilst allowing for the correction of the maximum PSII yield.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available