4.7 Article

Rationally defined safety factors for filter sizing

Journal

JOURNAL OF MEMBRANE SCIENCE
Volume 341, Issue 1-2, Pages 268-278

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.memsci.2009.06.015

Keywords

Safety factor; Process variability; Scale-up; Filter sizing

Ask authors/readers for more resources

Safety factors are empirical multipliers of a base case design filter area based on judgment. This analysis provides a rationale for assigning safety factor values based on designing a robust process that allows for scale differences, process variability, data extrapolation, and process expansion. It is applied to a variety of biopharmaceutical filter applications including final sterile filtration, dual sterile filtration, clarification, buffer sterilization. virus filtration, and ultrafiltration. Some filtration costs increase with area but there is an expected cost of failing to process the batch within a validated window of conditions that decreases with area. A variability factor is defined as the minimum cost area divided by a base case area. The base case area has a 50% chance of failing to process the batch when expected values of the process parameters are used. Variability factors can fall in the range of 1.1-2.5 for different filter applications. Process models combined with variability data are used to determine the sources and magnitude of process variability. The bioprocessing cases considered here imply that process variability generally arises primarily from feedstock and filter variability with operating conditions contributing as well for ultrafiltration. However, these relative proportions are very application specific. (C) 2009 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available