4.6 Article

The Effect of Textile-Based Inductive Coil Sensor Positions for Heart Rate Monitoring

Journal

JOURNAL OF MEDICAL SYSTEMS
Volume 38, Issue 2, Pages -

Publisher

SPRINGER
DOI: 10.1007/s10916-013-0002-0

Keywords

Sensor positions; Textile-based inductive coil sensor; Magnetic-induced conductivity sensing; Heart rate measurement; Ubiquitous healthcare

Funding

  1. Mid-Career Researcher Program through the National Research Foundation of Korea
  2. Ministry of Science, ICT & Future Planning [NRF-2012R1A2A2A04045455]
  3. National Research Foundation of Korea [2012R1A2A2A04045455] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

In the research related to heart rate measurement, few studies have been done using magnetic-induced conductivity sensing methods to measure the heart rate. The aim of this study was to analyze the effect of the position of a textile-based inductive coil sensor on the measurement of the heart rate. In order to assess the capability of the textile-based inductive coil sensor and the repeatability of measured cardiac muscle contractions, we proposed a new quality index based on the morphology of measured signals using a textile-based inductive coil sensor. We initially explored eight potential positions of the inductive sensor in a pilot experiment, followed by three sensor positions in the main experiment. A simultaneously measured electrocardiography (ECG) signal (Lead II) which was used as a reference signal for a comparison of the R-peak location with signals obtained from selected positions of the textile-based inductive coil sensor. The result of the main experiment indicated that the total quality index obtained from the sensor position 'P3', which was located 3 cm away from the left side from the center front line on the chest circumference line, was the highest (QI value = 1.30) among the three positions across all the subjects. This finding led us to conclude that (1) the position of the textile-based inductive coil sensor significantly affected the quality of the measurement results, and that (2) P3 would be the most appropriate position for the textile-based inductive coil sensor for heart rate measurements based on the magnetic-induced conductivity sensing principle.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available