Hydroxyapatite scaffolds with a multi modal porosity designed for use in tissue engineering of vascularized bone graft substitutes were prepared by three dimensional printing. Depending on the ratio of coarse (mean particle size 50 mu m) to fine powder (mean particle size 4 mu m) in the powder granulate and the sintering temperature total porosity was varied from 30% to 64%. While macroscopic pore channels with a diameter of 1 mm were created by CAD design, porosity structure in the sintered solid phase was governed by the granulate structure of the printing powder. Scaffolds sintered at 1,250 degrees C were characterized by a bimodal pore structure with intragranular pores of 0.3-0.4 mu m and intergranular pores of 20 mu m whereas scaffolds sintered at 1,400 degrees C exhibit a monomodal porosity with a maximum of pore size distribution at 10-20 mu m. For in-vivo testing, matrices were implanted subcutaneously in four male Lewis rats. Scaffolds with 50% porosity and an average pore size of similar to 18 mu m were successfully transferred to rats and vascularized within 4 weeks.