4.7 Article

Intertechnique Agreement and Interstudy Reproducibility of Strain and Diastolic Strain Rate at 1.5 and 3 Tesla: A Comparison of Feature-Tracking and Tagging in Patients With Aortic Stenosis

Journal

JOURNAL OF MAGNETIC RESONANCE IMAGING
Volume 41, Issue 4, Pages 1129-1137

Publisher

WILEY
DOI: 10.1002/jmri.24625

Keywords

feature tracking; tagging; aortic stenosis; Cardiac MRI

Funding

  1. British Heart Foundation [PG/07/068/2334]
  2. National Institute of Health Research (NIHR)
  3. National Institute for Health Research [PDF-2011-04-051] Funding Source: researchfish

Ask authors/readers for more resources

PurposeTo determine the interstudy reproducibility of myocardial strain and peak early-diastolic strain rate (PEDSR) measurement on cardiovascular magnetic resonance imaging (MRI) assessed with feature tracking (FT) and tagging, in patients with aortic stenosis (AS). Materials and MethodsCardiac MRI was performed twice (1-14 days apart) in 18 patients (8 at 1.5 Tesla [T], 10 at 3T) with moderate-severe AS. Circumferential peak systolic strain (PSS) and PEDSR were measured in all patients. Longitudinal PSS and PEDSR were assessed using FT in all patients, and tagging in the 3T sub-group. ResultsPSS was higher with FT than tagging (21.0 1.9% versus 17.0 +/- 3.4% at 1.5T, 21.4 +/- 4.0% versus 17.7 +/- 3.0% at 3T, P < 0.05), as was PEDSR (1.3 +/- 0.3 s(-1) versus 1.0 +/- 0.3 s(-1), P = 0.10 at 1.5T and 1.3 +/- 0.4 s(-1) versus 0.8 +/- 0.3 s(-1), P < 0.05 at 3T). The reproducibility of PSS was excellent with FT (coefficient of variation [CoV] 9-10%) and good with tagging at 1.5T (13-19%). Reproducibility of circumferential PEDSR was best at 1.5T when only basal/mid slices were included (CoV 12%), but moderate to poor at 3T (29-35%). Reproducibility of longitudinal strain was good with FT (10-16%) but moderate for PEDSR (approximate to 30%). ConclusionIn patients with AS, FT consistently produces higher values compared with tagging. The interstudy reproducibility of PSS is excellent with FT and good with tagging. The reproducibility of circumferential PEDSR at 1.5T is good when only basal and mid slices are used. J. Magn. Reson. Imaging 2015;41:1129-1137. (c) 2014 Wiley Periodicals, Inc.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available