4.7 Article

Comparison of Magnetic Resonance Feature Tracking for Systolic and Diastolic Strain and Strain Rate Calculation With Spatial Modulation of Magnetization Imaging Analysis

Journal

JOURNAL OF MAGNETIC RESONANCE IMAGING
Volume 41, Issue 4, Pages 1000-1012

Publisher

WILEY
DOI: 10.1002/jmri.24623

Keywords

cine magnetic resonance imaging; left ventricular function; tagging; feature tracking

Funding

  1. British Heart Foundation Clinical Research Training Fellowship [FS 11/17/28700]
  2. Birmingham NIHR/Wellcome Clinical Research Facility at the Queen Elizabeth Hospital
  3. UKCLRN
  4. British Heart Foundation [FS/11/17/28700] Funding Source: researchfish
  5. National Institute for Health Research [PDF-2012-05-205] Funding Source: researchfish

Ask authors/readers for more resources

PurposeTo compare cardiovascular magnetic resonance-feature tracking (CMR-FT) with spatial modulation of magnetization (SPAMM) tagged imaging for the calculation of short and long axis Lagrangian strain measures in systole and diastole. Materials and MethodsHealthy controls (n = 35) and patients with dilated cardiomyopathy (n = 10) were identified prospectively and underwent steady-state free precession (SSFP) cine imaging and SPAMM imaging using a gradient-echo sequence. A timed offline analysis of images acquired at identical horizontal long and short axis slice positions was performed using CMR-FT and dynamic tissue-tagging (CIMTag2D). Agreement between strain and strain rate (SR) values calculated using these two different methods was assessed using the Bland-Altman technique. ResultsAcross all participants, there was good agreement between CMR-FT and CIMTag for calculation of peak systolic global circumferential strain (-22.7 6.2% vs. -22.5 +/- 6.9%, bias 0.2 +/- 4.0%) and SR (-1.35 +/- 0.42 1/s vs. -1.22 +/- 0.42 1/s, bias 0.13 +/- 0.33 1/s) and early diastolic global circumferential SR (1.21 +/- 0.44 1/s vs. 1.07 +/- 0.30 1/s, bias -0.14 +/- 0.34 1/s) at the subendocardium. There was satisfactory agreement for derivation of peak systolic global longitudinal strain (-18.1 +/- 5.0% vs. -16.7 +/- 4.8%, bias 1.3 +/- 3.8%) and SR (-1.04 +/- 0.29 1/s vs. -0.95 +/- 0.32 1/s, bias 0.09 +/- 0.26 1/s). The weakest agreement was for early diastolic global longitudinal SR (1.10 +/- 0.40 1/s vs. 0.67 +/- 0.32 1/s, bias -0.42 +/- 0.40 1/s), although the correlation remained significant (r = 0.42, P < 0.01). CMR-FT generated these data over four times quicker than CIMTag. ConclusionThere is sufficient agreement between systolic and diastolic strain measures calculated using CMR-FT and myocardial tagging for CMR-FT to be considered as a potentially feasible and rapid alternative. J. Magn. Reson. Imaging 2015;41:1000-1012. (c) 2014 Wiley Periodicals, Inc.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available