4.7 Article

Reliability of Two-Dimensional and Three-Dimensional Pseudo-Continuous Arterial Spin Labeling Perfusion MRI in Elderly Populations: Comparison With 15O-Water Positron Emission Tomography

Journal

JOURNAL OF MAGNETIC RESONANCE IMAGING
Volume 39, Issue 4, Pages 931-939

Publisher

WILEY-BLACKWELL
DOI: 10.1002/jmri.24246

Keywords

cerebral blood flow (CBF); perfusion; arterial spin labeling (ASL); echo planner imaging (EPI); gradient and spin echo (GRASE); Alzheimer's disease (AD); magnetic resonance imaging (MRI); positron emission tomography (PET)

Funding

  1. NIH [R01-MH080892, R01-NS081077, R01-AG040770, R01-EB014922, P50-AG016570]
  2. Easton Consortium for Alzheimer's Disease Drug and Biomarker Discovery

Ask authors/readers for more resources

PurposeTo investigate the reliability and accuracy of two pseudo-continuous arterial spin labeling (pCASL) sequences, using two-dimensional (2D) gradient-echo echo planar imaging (EPI) and 3D gradient and spin echo (GRASE) as the readout, respectively. Materials and MethodsEach sequence was performed twice 4 weeks apart on six normal control subjects, six elderly subjects with mild cognitive impairment (MCI), and one participant with Alzheimer's disease (AD). Eight of these subjects also underwent (H2O)-O-15 positron emission tomography (PET) scans on the same day or proximal to their second MRI scan. The longitudinal repeatability of EPI and GRASE pCASL were evaluated with the intraclass correlation coefficient (ICC) and within-subject coefficient of variation (wsCV). ResultsThe ICCs of global perfusion measurements were 0.697 and 0.413 for GRASE and EPI based pCASL respectively. GRASE pCASL also demonstrated a higher longitudinal repeatability for regional perfusion measurements across 24 regions-of-interests (ICC = 0.707; wsCV = 10.9%) compared with EPI pCASL (ICC = 0.362; wsCV = 15.3%). When compared with PET, EPI pCASL showed a higher degree of spatial correlation with PET than GRASE pCASL, although the difference was not statistically significant. ConclusionThe 3D GRASE pCASL offers better repeatability than 2D EPI pCASL, thereby may provide a reliable imaging marker for the evaluation of disease progression and treatment effects in MCI and early AD subjects. J. Magn. Reson. Imaging 2014;39:931-939. (c) 2013 Wiley Periodicals, Inc.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available