4.3 Article

General expressions for the coupling coefficient, quality and filling factors for a cavity with an insert using energy coupled mode theory

Journal

JOURNAL OF MAGNETIC RESONANCE
Volume 242, Issue -, Pages 57-66

Publisher

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.jmr.2014.01.018

Keywords

Electron paramagnetic resonance; Dielectric resonators; Resonance cavity; Resonator modes; Coupled mode theory; Coupled modes; Coupling coefficient; Quality factor; Filling factor; Resonator frequency; Finite element methods; Magnetic field distributions; Electric field distributions; Spectrometer sensitivity; Signal-to-noise ratio

Funding

  1. Natural Sciences and Engineering Research Council of Canada
  2. University of New Brunswick
  3. Department of Electrical and Computer Engineering

Ask authors/readers for more resources

A cavity (CV) with a dielectric resonator (DR) insert forms an excellent probe for the use in electron paramagnetic resonance (EPR) spectrometers. The probe's coupling coefficient, K, the quality factor, Q and the filling factor, n are vital in assessing the EPR spectrometer's performance. Coupled mode theory (CMT) is used to derive general expressions for these parameters. For large permittivity the dominating factor in it is the ratio of the DR and CV cross sectional areas rather than the dielectric constant. Thus in some cases, resonators with low dielectric constant can couple much stronger with the cavity than do resonators with a high dielectric constant. When the DR and CV frequencies are degenerate, the coupled n is the average of the two uncoupled ones. In practical EPR probes the coupled 17 is approximately half of that of the DR. The Q of the coupled system generally depends on the eigenvectors, uncoupled frequencies (omega(1), omega(2)) and the individual quality factors (Q(1), Q(2)). It is calculated for different probe configurations and found to agree with the corresponding HFSS (R) simulations. Provided there is a large difference between the Q(1) Q2 pair and the frequencies of DR and CV are degenerate, Q is approximately equal to double the minimum of Q(1) and Q(2). In general, the signal enhancement ratio, I-with (insert)/I-empty, is obtained from Q and n. For low loss DRs it only depends on n(1)/n(2). However, when the DR has a low Q, the uncoupled Qs are also needed. In EPR spectroscopy it is desirable to excite only a single mode. The separation between the modes, phi, is calculated as a function of k and Q. It is found to be significantly greater than five times the average bandwidth. Thus for practical probes, it is possible to excite one of the coupled modes without exciting the other. The CMT expressions derived in this article are quite general and are in excellent agreement with the lumped circuit approach and finite numerical simulations. Hence they can also be applied to a loop-gap resonator in a cavity. For the design effective EPR probes, one needs to consider the it, Q and n parameters. (C) 2014 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available