4.7 Article

Highly Sensitive Detection of Malaria Parasitemia in a Malaria-Endemic Setting: Performance of a New Loop-Mediated Isothermal Amplification Kit in a Remote Clinic in Uganda

Journal

JOURNAL OF INFECTIOUS DISEASES
Volume 208, Issue 4, Pages 645-652

Publisher

OXFORD UNIV PRESS INC
DOI: 10.1093/infdis/jit184

Keywords

malaria; diagnosis; LAMP; loop-mediated isothermal amplification; sensitivity and specificity; PCR; polymerase chain reaction; molecular diagnosis; DNA; Plasmodium falciparum; Uganda; Africa

Funding

  1. Foundation for Innovative New Diagnostics through Bill and Melinda Gates Foundation
  2. Ministry of Foreign Affairs of the Government of the Netherlands
  3. United Kingdom Department for International Development

Ask authors/readers for more resources

Background. Current malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections. Molecular methods such as polymerase chain reaction (PCR) are highly sensitive but remain too complex for field deployment. A new commercial molecular assay based on loop-mediated isothermal amplification (LAMP) was assessed for field use. Methods. Malaria LAMP (Eiken Chemical, Japan) was evaluated for samples from 272 outpatients at a rural Ugandan clinic and compared with expert microscopy, nested PCR, and quantitative PCR (qPCR). Two technicians performed the assay after 3 days of training, using 2 alternative blood sample-preparation methods and visual interpretation of results by fluorescence assay. Results. Compared with 3-well nested PCR, the sensitivity of both LAMP and single-well nested PCR was 90%; the microscopy sensitivity was 51%. For samples with a Plasmodium falciparum qPCR titer of >= 2 parasites/mu L, LAMP sensitivity was 97.8% (95% confidence interval, 93.7%-99.5%). Most false-negative LAMP results involved samples with parasitemia levels detectable by 3-well nested PCR but very low or undetectable by qPCR. Conclusions. Malaria LAMP in a remote Ugandan clinic achieved sensitivity similar to that of single-well nested PCR in a United Kingdom reference laboratory. LAMP dramatically lowers the detection threshold achievable in malaria-endemic settings, providing a new tool for diagnosis, surveillance, and screening in elimination strategies.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available