4.2 Article

Preparation and quality control of silver nanoparticle-antibody conjugate for use in electrochemical immunoassays

Journal

JOURNAL OF IMMUNOLOGICAL METHODS
Volume 387, Issue 1-2, Pages 262-269

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jim.2012.11.003

Keywords

Silver colloid; Antibody; Immobilization; Electrochemical immunoassay

Funding

  1. UK Government's Department of Industry, Universities and Skills (DIUS) as part of the National Measurement System

Ask authors/readers for more resources

Metal nanoparticle-antibody conjugates are often used as optical or electrochemical markers in applications like immunohistochemistry, lateral flow tests, biosensors and immunoassays. In order to serve that role, an antibody needs to be immobilized on the surface of the nanoparticle. This is easily done, as proteins bind to gold and silver nanoparticles spontaneously. However, this immobilization process might result in nanoparticle aggregation or the loss of the bioactivity of the conjugated antibodies. In this work the optimization of antibody immobilization on silver colloid in order to obtain conjugates with the best possible activity is investigated. The parameters investigated were the type of immobilization buffer, its molarity and pH, the nanoparticle/ antibody ratio and also blocking and washing protocols to reduce non-specific binding. The functionality of the obtained conjugates was tested with electrochemical immunoassay. It was found out that the optimum environment for immobilization of an anti-myoglobin antibody on silver nanopartides was 0.2 M boric acid pH 6.5 with 10 mu g of antibody loading per 1 mL of silver colloid. For an anti-troponin antibody it was 0.1 M boric acid pH 7.5 also with 10 mu g/mL of antibody loading. The main problem for silver conjugation was the tendency of silver nanoparticles to aggregate during the immobilization process, but by choosing the optimum conditions the aggregation problem was completely removed. Here it is demonstrated that by using the conjugates prepared with an optimized protocol an increase in the sensitivity of the assay 10 times can be achieved. The electrochemical immunoassay described here can be used as a test for quality control of conjugates and for the estimation of batch-to-batch variability. (C) 2012 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available