4.2 Article

Delayed processing of blood increases the frequency of activated CD11b+CD15+granulocytes which inhibit T cell function

Journal

JOURNAL OF IMMUNOLOGICAL METHODS
Volume 341, Issue 1-2, Pages 68-75

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jim.2008.10.019

Keywords

Blood processing; Granulocytes; CD11b; CD15; T cells; T cell inhibition

Ask authors/readers for more resources

We tested whether granulocytes, which contaminate PBMC isolates after prolonged blood storage at room temperature, are responsible for inhibited T cell function in aged blood. We extend previous observations by characterizing these contaminating granulocytes as CD11b+ CD15+ cells comparable to activated CD11b+ CD15+ granulocytes induced by incubation of blood with FMLP. Granulocyte contamination of PBMC was observed within 6-8 h after venipuncture and room temperature storage (2.3 fold increase), and increased 11.3-fold by 24-26 h in comparison to PBMC from fresh blood. Refrigerated 22-26 hour storage of blood exacerbated granulocyte contamination (84-fold increase). In contrast, granulocyte contamination was markedly reduced if blood was diluted in RPMI-1640 medium (3.9-fold increase) or PBS (1.8-fold increase) prior to 22-26 hour room temperature storage. Granulocyte contamination significantly correlated with reduced CD3 zeta chain expression, a marker of T cell dysfunction. Correspondingly, T cell proliferation following PHA stimulation was significantly decreased in PBMC with contaminating granulocytes from aged blood (77% of control) or FMLP treated blood (44% of control). Minimizing granulocyte contamination in PBMC of aged blood by cell sorting, or by reducing granulocyte activation by diluting blood in PBS prior to storage, increased CD3 zeta chain expression and increased T cell proliferation following stimulation. These data indicate that granulocytes inhibit T cell function in aged blood. Therefore, preventing granulocyte activation in blood specimens is critical to maintain optimal T cell function. This may be accomplished by limiting the time from venipuncture to PBMC isolation to <8 h and may be extended to 26 h by simply diluting blood in PBS prior to room temperature storage. (C) 2008 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available