4.8 Article

Energy and economic analysis of geothermal-solar trigeneration systems: A case study for a hotel building in Ischia

Journal

APPLIED ENERGY
Volume 138, Issue -, Pages 224-241

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2014.10.076

Keywords

ORC (Organic Rankine Cycles); Geothermal energy; Solar energy; Dynamic energy performance simulation; Absorption chiller

Ask authors/readers for more resources

This paper presents the design, simulation and optimisation of a small trigeneration plant supplied by geothermal and solar energies. Different technologies are implemented in a dynamic simulation model purposely developed for research scope: a 6 kW(e) micro Organic Rankine Cycle (ORC); a 30 kW(f) single stage H2O/LiBr absorption chiller; a geothermal well; a solar field obtained by new prototypal flat-plate evacuated solar collectors. The ORC is supplied by heat obtained by a geothermal well in which geothermal brine is about at 95 degrees C. In order to improve system performance, additional heat is provided by solar energy obtained through a 25 m(2) solar field. Diathermic oil (up to 130 degrees C) is adopted as working fluid in order to supply heat to the ORC evaporator. A suitable oil storage tank is modelled in order to mitigate the temperature fluctuations due to the variability of solar energy availability. The output power of the ORC depends on the availability of solar energy. The absorption chiller is switched-on in summer time and it is fed by geothermal energy only. This simulation model is implemented in TRNSYS environment The ORC is modelled by zero-dimensional energy and mass balances implemented in Engineering Equation Solver (EES). A case study is developed in order to test the energy and economic performance of this innovative micro-trigeneration plant. In particular, the above mentioned model is applied to the Regina Isabella hotel in Ischia (Naples, South Italy), famous for its geothermal sources. Currently, such hotel is already equipped by a geothermal system (by several hot water wells) for thermal cares, domestic hot water production and space heating. By TRNSYS the optimisation of the system design parameters and the calculation of the thermo-economic conditions were performed. The system showed excellent energy performance indexes. In fact, the average yearly efficiency of the solar thermal collectors is close to 60%, whereas the average yearly ORC electric efficiency is about 6%, which is a good achievement considering the system driving temperature. Results also show that the system performance is more dependent on the availability of the geothermal energy than the solar one. From the economic point of view, good results are also obtained. In fact, in the worst operating conditions the Simple Pay Back Period is 7.6 years, decreasing to 2.5 years in the most convenient considered scenario (public funding and full utilisation of the produced thermal energy). (C) 2014 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available