Journal
JOURNAL OF HAZARDOUS MATERIALS
Volume 163, Issue 2-3, Pages 1076-1083Publisher
ELSEVIER SCIENCE BV
DOI: 10.1016/j.jhazmat.2008.07.074
Keywords
CEPT; Chromium; COD; Coagulants; Wastewater characteristics; Tannery wastewater
Categories
Funding
- University of Engineering and Technology, Lahore, Pakistan
Ask authors/readers for more resources
Chemically enhanced primary treatment (CEPT) is a technology that uses coagulants for enhanced pollutants removal at the primary stage of the wastewater treatment. This paper presents the detailed characteristics of tannery wastewater. It also explains effectiveness of CEPT in removing pollutants from tannery wastewater using Various metal salts. The results of this study demonstrated that the tannery effluent had high concentrations of organic matter, solids, sulfates, sulfides and chromium. Alum, ferric chloride and ferric sulfate were tested as coagulants using jar test apparatus. Alum was found to be the suitable coagulant for tannery wastewater in a dose range of 200-240 mg/L as Al-2(SO4)(3). With alum, percentage removal efficiency for turbidity, total suspended solids (TSS), chemical oxygen demand (COD) and chromium was found to be 98.7-99.8, 94.3-97.1, 53.3-60.9, and 98.9-99.7%, respectively. National effluent quality standards for total suspended solids and chromium were met after CEPT. However, COD content was high, emphasizing the need of secondary treatment for the tannery effluent. (C) 2008 Elsevier B.V. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available