4.2 Article

Reconstruction of a 4-cm human median nerve gap by including an autogenous nerve slice in a bioabsorbable nerve conduit: Case report

Journal

JOURNAL OF HAND SURGERY-AMERICAN VOLUME
Volume 33A, Issue 3, Pages 313-315

Publisher

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/j.jhsa.2007.12.008

Keywords

conduit; nerve; nerve growth factor; Schwann cell

Ask authors/readers for more resources

Nerve gaps up to 3 cm in length can be reconstructed in the human with a bioabsorbable nerve conduit; however, nerve gaps greater than 3 cm have not been reconstructible in animal models unless a neurotrophic factor, like cultured Schwann cells, was added to the nerve conduit. It is the purpose of this article to present the result of human nerve regeneration across a 4-cm nerve gap in the median nerve at the wrist when a slice of autogenous normal nerve was placed into the middle of a bioabsorbable nerve conduit.m

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available