4.2 Article

Underdrain Configuration to Enhance Bioretention Exfiltration to Reduce Pollutant Loads

Journal

JOURNAL OF ENVIRONMENTAL ENGINEERING
Volume 137, Issue 11, Pages 1082-1091

Publisher

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)EE.1943-7870.0000437

Keywords

Internal water storage (IWS) zone; Bioretention; Hydrology; Water quality; Drainage configuration; Coastal plain; Exfiltration; Low impact development

Funding

  1. Cooperative Institute for Coastal and Estuarine Environmental Technology (CICEET)

Ask authors/readers for more resources

The bioretention drainage configuration of raising the outlet to create an internal water storage (IWS) layer in the media was originally intended to promote denitrifying conditions. The goal was to reduce nitrate and total nitrogen concentrations in nutrient-sensitive watersheds. Two field studies in the Piedmont region of North Carolina, where the in situ soils typically have high clay content, showed this design feature had potential to enhance exfiltration and reduce drainage from bioretention. Two bioretention cells in Rocky Mount, North Carolina, were monitored for two year-long periods to measure the impact of varying IWS zone depths over sandier underlying soils. Nearly 99% of runoff entering the bioretention cell with sand underlying soil (sand cell) was never directly discharged to the storm water network. However, the hydraulic retention time (contact time) of runoff in the media was less than 3 h, and except for total suspended solids (TSS), minimal pollutant removal was achieved. The other bioretention cell had a sandy clay loam underlying soil (SCL cell); the percentage of runoff leaving via exfiltration and evapotranspiration from this cell was 87% during the monitoring period with a 1.03-m IWS zone depth and 75% when the IWS zone depth was 0.73 m. The underlying soil of the SCL cell had a lower hydraulic conductivity, so water would remain in the IWS zone for up to 7 days. The increased hydraulic retention time in the media resulted in lower outflow concentrations. For events monitored with drainage from the SCL cell, efficiency ratios of all the nitrogen species and TSS exceeded 0.5. As an additional metric of performance, the parking lot runoff and treated runoff from both the SCL and sand cells were compared to concentrations consistent with good and fair benthic macroinvertebrate health in streams. Using this metric, the parking lot runoff only met the fair standard for total nitrogen (TN) and total phosphorus (TP), and treated runoff from the SCL cell achieved the good standard for both TN and TP. However, because of the short hydraulic retention time of runoff in the media for the sand cell, this cell only maintained the fair standard for TN and did not achieve the fair standard for TP. DOI: 10.1061/(ASCE)EE.1943-7870.0000437. (C) 2011 American Society of Civil Engineers.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available