4.4 Article

Impact of Carotid Stent Cell Design on Vessel Scaffolding: A Case Study Comparing Experimental Investigation and Numerical Simulations

Journal

JOURNAL OF ENDOVASCULAR THERAPY
Volume 18, Issue 3, Pages 397-406

Publisher

SAGE PUBLICATIONS INC
DOI: 10.1583/10-3338.1

Keywords

carotid artery; stent; cell design; vessel scaffolding; finite element analysis

Funding

  1. MIUR (Ministero dell'Istruzione, dell'Universita e della Ricerca, Italian Ministry of Education, University and Research)
  2. University of Ghent [01SF1308]
  3. Cariplo Foundation [2009.2822]
  4. Research Foundation - Flanders (FWO) [G.0100.08]

Ask authors/readers for more resources

Purpose: To quantitatively evaluate the impact of carotid stent cell design on vessel scaffolding by using patient-specific finite element analysis of carotid artery stenting (CAS). Methods: The study was organized in 2 parts: (1) validation of a patient-specific finite element analysis of CAS and (2) evaluation of vessel scaffolding. Micro-computed tomography (CT) images of an open-cell stent deployed in a patient-specific silicone mock artery were compared with the corresponding finite element analysis results. This simulation was repeated for the closed-cell counterpart. In the second part, the stent strut distribution, as reflected by the inter-strut angles, was evaluated for both cell types in different vessel cross sections as a measure of scaffolding. Results: The results of the patient-specific finite element analysis of CAS matched well with experimental stent deployment both qualitatively and quantitatively, demonstrating the reliability of the numerical approach. The measured inter-strut angles suggested that the closed-cell design provided superior vessel scaffolding compared to the open-cell counterpart. However, the full strut interconnection of the closed-cell design reduced the stent's ability to accommodate to the irregular eccentric profile of the vessel cross section, leading to a gap between the stent surface and the vessel wall. Conclusion: Even though this study was limited to a single stent design and one vascular anatomy, the study confirmed the capability of dedicated computer simulations to predict differences in scaffolding by open-and closed-cell carotid artery stents. These simulations have the potential to be used in the design of novel carotid stents or for procedure planning. J Endovasc Ther. 2011; 18: 397-406

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available