4.6 Article

Color difference thresholds in dental ceramics

Journal

JOURNAL OF DENTISTRY
Volume 38, Issue -, Pages E57-E64

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.jdent.2010.07.008

Keywords

CIEDE2000; CIELAB; Acceptability thresholds; Perceptibility thresholds; Fuzzy Approximation; Dental ceramics

Funding

  1. Ministerio de Ciencia e Innovacion (Spain) [MAT2009-09795, SAF2010-20558]

Ask authors/readers for more resources

Objectives: The objective of the study was to determine the perceptibility and acceptability thresholds for dental ceramics using CIEDE2000 (Delta E-00) and CIELAB (Delta E*(ab)) color difference formulas and a novel TSK Fuzzy Approximation. Methods: A 13-observer panel performed independent observations of perceptibility and acceptability judgments on 105 pairs of ceramic discs (14 mm in diameter and 3mm thick). Color differences of the disc pairs were calculated using both color difference formulas (Delta E-00 ranged from 0.10 to 9.91). Two fitting procedures were used: S-shaped curve and TSK Fuzzy Approximation. For both procedures, from the resultant fitting curves, the 95% confidence intervals were estimated and the 50:50% thresholds were calculated (50% positive and 50% negative answers). Results: With the S-shaped fitting procedure, a 50: 50% acceptability threshold was found to be Delta E-00 = 2.25 (r(2) = 0.88) and Delta E*(ab) 3.46 (r(2) = 0.85). Corresponding values with a TSK Fuzzy Approximation were Delta E-00 = 2.23 (r(2) = 0.89) and Delta E*(ab) 3.48 (r(2) = 0.86). The perceptibility thresholds for fitted S-shape curves were Delta E-00 = 1.30 (r(2) = 0.74) and Delta E*(ab) 1: 80 (r(2) = 0.70) and Delta E-00 = 1.25 (r(2) = 0.75), and Delta E*(ab) 1.74 (r(2) = 0.71) for the TSK Fuzzy Approximation. The Delta L', Delta C', Delta H' values corresponding to a 50% acceptability threshold were Delta L' = 2.44, Delta C' = 3.15 and Delta H' = 3.24 respectively. Conclusions: The CIEDE2000 color difference formula provided a better fit than CIELAB formula in the evaluation of color difference thresholds of dental ceramics. There was a statistically significant difference between perceptibility and acceptability thresholds for dental ceramics. The TSK Fuzzy Approximation has been proved to be a reliable alternative approach for the color threshold calculation procedure. (C) 2010 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available