4.6 Article

Evaluation of multiple test methods for the detection of the novel 2009 influenza A (H1N1) during the New York City outbreak

Journal

JOURNAL OF CLINICAL VIROLOGY
Volume 45, Issue 3, Pages 191-195

Publisher

ELSEVIER
DOI: 10.1016/j.jcv.2009.06.005

Keywords

Novel influenza A; Influenza H1N1; Influenza H3N2; RVP

Categories

Ask authors/readers for more resources

Background: In response to the novel influenza A HI NI outbreak in the NY City area, 6090 patient samples were submitted over a 5-week period for a total of 14,114 viral diagnostic tests, including rapid antigen, direct immunofluorescence (DFA), viral culture and PCR. Little was known about the performance of the assays for the detection of novel H1N1 in the background of seasonal H1N1, H3N2 and other circulating respiratory viruses. In addition, subtyping influenza A became critical for the identification of high risk and/or hospitalized patients with novel H1N1 infection and for monitoring the spread of the outbreak. Study design: This study analyzed the performances of the BinaxNOW Influenza A&B test (BinaxNOW), the 3M Rapid Detection Flu A + B test (3MA + B), direct immunofluorescence, R-Mix culture and the Luminex xTAG Respiratory Virus Panel (RVP) for the detection of seasonal influenza, novel H1N1 and other respiratory viruses. RVP was also evaluated for its ability to differentiate seasonal H1N1, H3N2 and novel H1N1. Results: The sensitivities. specificities, PPVs and NPVs for the detection of novel H1N1, determined by comparing all four-test methods, were: rapid antigen: 17.8%, 93.6%, 77.4%, 47.9%; DFA: 46.7%, 94.5%, 91.3%, 58.9%; R-Mix culture: 88.9%, 100%, 100%, 87.9%: RVP: 97.8%, 100%, 100%, 97.3%. The individual sensitivities of BinaxNOW and 3MA+B as compared to R-Mix culture for the detection of novel HI NI were 9.6% and 40%, respectively. All unsubtypeable influenza A specimens identified by RVP and tested with the CDC novel HI NI specific RT-PCR assay were confirmed to be novel H1N1. Conclusions: Rapid antigen tests, DFA, R-Mix culture and the xTAG RVP test all detected the novel H1N1 strain, but with highly varied sensitivity. The RVP test provided the best diagnostic option as RVP demonstrated superior sensitivity for the detection of all influenza strains, including the novel HI NI, provided accurate influenza A subtyping and identified a significant number of additional respiratory pathogens. (C) 2009 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available