4.8 Article

A Randomized Trial of Intrapartum Fetal ECG ST-Segment Analysis

Journal

NEW ENGLAND JOURNAL OF MEDICINE
Volume 373, Issue 7, Pages 632-641

Publisher

MASSACHUSETTS MEDICAL SOC
DOI: 10.1056/NEJMoa1500600

Keywords

-

Funding

  1. Eunice Kennedy Shriver National Institute of Child Health and Human Development
  2. Neoventa Medical

Ask authors/readers for more resources

BACKGROUND It is unclear whether using fetal electrocardiographic (ECG) ST-segment analysis as an adjunct to conventional intrapartum electronic fetal heart-rate monitoring modifies intrapartum and neonatal outcomes. METHODS We performed a multicenter trial in which women with a singleton fetus who were attempting vaginal delivery at more than 36 weeks of gestation and who had cervical dilation of 2 to 7 cm were randomly assigned to open or masked monitoring with fetal ST-segment analysis. The masked system functioned as a normal fetal heart-rate monitor. The open system displayed additional information for use when uncertain fetal heart-rate patterns were detected. The primary outcome was a composite of intrapartum fetal death, neonatal death, an Apgar score of 3 or less at 5 minutes, neonatal seizure, an umbilical-artery blood pH of 7.05 or less with a base deficit of 12 mmol per liter or more, intubation for ventilation at delivery, or neonatal encephalopathy. RESULTS A total of 11,108 patients underwent randomization; 5532 were assigned to the open group, and 5576 to the masked group. The primary outcome occurred in 52 fetuses or neonates of women in the open group (0.9%) and 40 fetuses or neonates of women in the masked group (0.7%) (relative risk, 1.31; 95% confidence interval, 0.87 to 1.98; P = 0.20). Among the individual components of the primary outcome, only the frequency of a 5-minute Apgar score of 3 or less differed significantly between neonates of women in the open group and those in the masked group (0.3% vs. 0.1%, P = 0.02). There were no significant between-group differences in the rate of cesarean delivery (16.9% and 16.2%, respectively; P = 0.30) or any operative delivery (22.8% and 22.0%, respectively; P = 0.31). Adverse events were rare and occurred with similar frequency in the two groups. CONCLUSIONS Fetal ECG ST-segment analysis used as an adjunct to conventional intrapartum electronic fetal heart-rate monitoring did not improve perinatal outcomes or decrease operative-delivery rates. (Funded by the Eunice Kennedy Shriver National Institute of Child Health and Human Development and Neoventa Medical; ClinicalTrials.gov number, NCT01131260.)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available