4.4 Article

Effect of a Patient Navigator Program on the Volume and Quality of Colonoscopy

Journal

JOURNAL OF CLINICAL GASTROENTEROLOGY
Volume 45, Issue 5, Pages E47-E53

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MCG.0b013e3181f595c3

Keywords

colonoscopy; colorectal neoplasms; urban health

Funding

  1. NCI NIH HHS [T32 CA009529-22, T32 CA095929, R43 CA095929, T32 CA009529] Funding Source: Medline
  2. NICHD NIH HHS [T32 HD007430] Funding Source: Medline

Ask authors/readers for more resources

Background and Goals: To increase colorectal cancer screening among urban minorities, New York Presbyterian Hospital/Columbia University, with support from the New York City Department of Health and the Citywide Colon Cancer Control Coalition (C5), instituted a patient navigation and direct endoscopic referral system. We assessed the effect of this program on the volume of colonoscopy in this institution, which caters to a socioeconomically diverse patient population. Study: We compared colonoscopy volume during the first year of the navigator program with the volume during the year before this program. We stratified on Medicaid status to assess the secular trend of screening rates. To assess quality during this period, we measured cecal intubation rates, preparation quality, and adenoma detection rates. Results: Of the 749 patients assessed by the patient navigators, 678 (91%) underwent colonoscopy. Colonoscopy volume among the Medicaid outpatients increased by 56% ( 957 to 1489). Adenoma detection was 27% and the cecal intubation rate was 97%. Comparing navigated patients with the nonnavigated Medicaid outpatients, preparation quality was superior (34% vs. 40% suboptimal, P = 0.0282), although preparation quality remained inferior to that of private patients (20% suboptimal, P < 0.0001). Conclusions: Volume of the colonoscopy increased, coinciding with the onset of the patient navigation program. This increase was nearly entirely owing to a rise in the colonoscopies among Medicaid outpatients, the principal focus of the navigator program. This increase in quantity was accomplished while maintaining an overall high level of quality as measured by cecal intubation rates and adenoma detection, although preparation quality requires further efforts at improvement.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available