4.6 Article

Using a postcolumn-infused internal standard for correcting the matrix effects of urine specimens in liquid chromatography-electrospray ionization mass spectrometry

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1327, Issue -, Pages 97-104

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2013.12.066

Keywords

Postcolumn-infused internal standard (PCI-IS); Benzodiazepine (BZD); Matrix effects; Urine concentrations; LC-ESI-MS

Funding

  1. National Science Council of Taiwan [NSC 102-2325-B-002-037, NSC 102-2319-B-002-002]

Ask authors/readers for more resources

Matrix effects (MEs) are a major problem affecting the quantitative accuracy of liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) when analyzing complicated samples. While analyzing urine specimens, the wide diversity of endogenous materials and different urine concentrations may result in inaccurate quantification. In this study, we propose a postcolumn-infused internal standard (PCI-IS) strategy for universal correction of MEs in urine specimens. MEs can be effectively corrected by dividing the target analyte signal intensity by the PCI-IS intensity. To evaluate the performance of PCI-IS, we used 6 benzodiazepine (BZD) drugs in 5 different concentrations of urine matrixes as a test model. The divergence of the BZD drug signal responses in 5 different urine matrixes was expressed using their respective coefficients of variation (CV) to evaluate the efficiency of using PCI-IS in correcting matrix effects. The CV of the BZD drug signal intensities in these 5 different concentrations of the urine matrixes were reduced from 10 to 30% to less than 10% when the PCI-IS correction method was employed. When the PCI-IS method was used to correct the 6 BZDs in 25 real human urine samples, over 90% of the test results exhibited quantification errors of less than 20%, and all of the test results had quantification errors of less than 30%. These results demonstrate that the PCI-IS method can resolve the problem of inaccurate quantification that arises from the diversity of urine specimens. The PCI-IS method is particularly useful for clinical analysis or forensic toxicology to improve the quantification accuracy in an economical way. (C) 2014 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available