4.6 Article

Targeted profiling of polar intracellular metabolites using ion-pair-high performance liquid chromatography and -ultra high performance liquid chromatography coupled to tandem mass spectrometry: Applications to serum, urine and tissue extracts

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1349, Issue -, Pages 60-68

Publisher

ELSEVIER
DOI: 10.1016/j.chroma.2014.05.019

Keywords

Metabolite profiling; HILIC; Porous graphitic carbon; Ion pair chromatography; Mass spectrometry; Central carbon metabolism

Funding

  1. European Union (European Social Fund - ESF)
  2. Greek national funds through the Operational Program Education and Lifelong Learning of the National Strategic Reference Framework (NSRF) - Research Funding Program: Heracleitus II

Ask authors/readers for more resources

The effective analysis of polar ionic metabolites by LC-MS, such as those encountered in central carbon metabolism, represents a major problem for metabolic profiling that is not adequately addressed using strategies based on either reversed-phase or HILIC methods. Here we have compared analysis of central carbon metabolites on optimized methods using HILIC, porous graphitic carbon or ion pair chromatography (IPC) using tributyl ammonium as IF reagent. Of the 3 chromatographic approaches examined only IPC enabled us to obtain a robust analytical methodology. This system was used to profile more than a hundred endogenous metabolic intermediates in urine, serum and tissue samples. However, whilst we found IPC to be the best of the approaches examined considerable care was still needed to obtain robust data. Thus, in excess of 40 of representative biological samples were needed to condition a new analytical column and further 10 matrix injections were then required at the beginning of each analytical batch in order to obtain robust and reproducible chromatographic separations. An additional limitation that we have found was that, for a small number of phosphorylated and poly carboxylic acid metabolites, measurement was only possible if the analytes were present in relatively high concentrations. We also found that, whilst this methodology could be used for the analysis of both in vitro cell culture media, cell extracts, tissue, and biological fluids (blood, urine), for the best results columns should only be used to analyze a single matrix. However, despite the need for extensive column conditioning, and the manifold disadvantages resulting from the contamination of the separation system and mass spectrometer with the ion pair reagent, IPC-MS currently provides the best means of analyzing these polar, ionic and problematic metabolites. (C) 2014 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available