4.6 Article

Monolithic molecularly imprinted polymeric capillary columns for isolation of aflatoxins

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1364, Issue -, Pages 163-170

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2014.08.078

Keywords

Aflatoxins; Capillary liquid chromatography; Molecularly imprinted polymers; Monolithic column; Photopolymerization

Funding

  1. Ministry of Science (Warsaw, Poland) grant [N N204 012038]
  2. National Science Center (Krakow, Poland) grant [2011/01/B/ST4/00543]
  3. Kujawsko-Pomorskie Voivodship Budget Krok w przyszlosc

Ask authors/readers for more resources

Monolithic molecularly imprinted polymers extraction columns have been prepared in fused-silica capillaries by UV or thermal polymerization in a two-step process. First, a poly-(trimethylolpropane trimethacrylate) (polyTRIM) core monolith was synthesized either by UV or thermal polymerization. Then it was grafted with the mixture of methacrylic acid (MAA) as a functional monomer, ethylene dimethacrylate (EDMA) as a cross-linking agent, 5,7-dimethoxycoumarin (DMC) as an aflatoxin-mimicking template, toluene as a porogen solvent and 2,2-azobis-(2-methylpropionitrile) (AIBN) as an initiator of the polymerization reaction. Different thermal condition of the photografting and different concentrations of the grafting mixture were tested during polymerization. The extraction capillary columns were evaluated in the terms of their hydrodynamic and chromatographic properties. Retention coefficients for aflatoxin B1 and DMC were used for assessment of the selectivity and imprinting factor. The obtained results indicate that the temperature of photografting and concentration of the grafting mixture are key parameters that determine the quality of the prepared MIPs. From the MIP columns characterized by the highest permeability the column of the highest imprinting factor was applied for isolation of aflatoxins B1, B2, G1 and G2 from the model aqueous sample followed by on-line chromatographic separation. The process was performed using a micro-MISPE-microLC-LIF system of a novel design, which allowed for detection of the eluates from the sample preparation part as well as from the chromatographic separation. (C) 2014 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available