4.6 Article

Dispersive liquid-liquid microextraction for the determination of phenols by acetonitrile stacking coupled with sweeping-micellar electrokinetic chromatography with large-volume injection

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1361, Issue -, Pages 291-298

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2014.08.013

Keywords

Dispersive liquid-liquid microextraction; Capillary electrophoresis; Acetonitrile stacking; Sweeping; Phenols

Funding

  1. Northwest AF University [Z111021005]
  2. National Natural Science Foundation of China (NSFC) [41271244]

Ask authors/readers for more resources

The current routes to couple dispersive liquid-liquid microextraction (DLLME) with capillary electrophoresis (CE) are evaporation of water immiscible extractants and backextraction of analytes. The former is not applicable to extractants with high boiling points, the latter being effective only for acidic or basic analytes, both of which limit the further application of DLLME-CE. In this study, with 1-octanol as a model DLLME extractant and six phenols as model analytes, a novel method based on acetonitrile stacking and sweeping is proposed to accomplish large-volume injection of 1-octanol diluted with a solvent-saline mixture before micellar electrokinetic chromatography. Brij-35 and beta-cyclodextrin were employed as pseudostationary phases for sweeping and also for improving the compatibility of sample zone and aqueous running buffer. A short solvent-saline plug was used to offset the adverse effect of the water immiscible extractant on focusing efficiency. The key parameters affecting separation and concentration were systematically optimized; the effect of Brij-35 and 1-octanol on focusing mechanism was discussed. Under the optimized conditions, with similar to 30-fold concentration enrichment by DLLME, the diluted extractant (8x) was then injected into the capillary with a length of 21 cm (42% of the total length), which yielded the overall improvements in sensitivity of 170-460. Limits of detection and qualification ranged from 0.2 to 1.0 ng/mL and 1.0 to 3.4 g/mL, respectively. Acceptable repeatability lower than 3.0% for migration time and 9.0% for peak areas were obtained. The developed method was successfully applied for analysis of the phenol pollutants in real water samples. (C) 2014 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available