4.6 Article

Rapid liquid chromatography-tandem mass spectrometry-based method for the analysis of alcohol ethoxylates and alkylphenol ethoxylates in environmental samples

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1305, Issue -, Pages 154-163

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2013.07.017

Keywords

Liquid chromatography-tandem mass spectrometry; Alcohol ethoxylates; Alkylphenol ethoxylates; Solid-phase extraction; Nonionic surfactants

Funding

  1. United States Environmental Protection Agency, through its Office of Research and Development

Ask authors/readers for more resources

A sensitive and selective method for the determination of alcohol ethoxylates (AEOs) and alkylphenol ethoxylates (APEOs) using solid-phase extraction (SPE) and LC-MS/MS was developed and applied to the analysis of water samples. All AEO and APEO homologues, a total of 152 analytes, were analyzed within a run time of 11 min, and the MS allowed for the detection of ethoxymers containing 2-20 ethoxy units (eta(EO) = 2-20). The limits of detection (LOD) were as low as 0.1 pg injected, which generally increased as eta(EO) increased (e.g., as high as 300 pg for eta(EO) =20). Additionally, the responses of the various ethoxymers varied by orders of magnitude, with ethoxymers with eta(EO) = 3-5 being the most sensitive and those with eta(EO) > 15 producing the least response in the MS. Absolute extraction recoveries of the analytes ranged from 37% to 69% in ultrapure water (RSD <= 20%), with the recovery depending on the length of the alkyl chain. Abiotic stability studies were performed, and C14-18 ethoxylates showed significant degrees of degradation. Water samples from the Colorado River were then analyzed for AEOs and APEOs, with absolute extraction recoveries ranging from 33% to 45% (RSD <= 12%). The predominant species observed in most samples were the octylphenol (OP) and nonylphenol (NP) ethoxylates, which contained total concentrations that were greater than 100 ng/L APEOs in a couple samples. Other AEO homologues were identified in the river water samples, including C-13, C-16, C-16, and C-18 ethoxylates, but these compounds. were generally present at much lower levels (i.e., <50 ng/L total concentration). Published by Elsevier B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available