4.6 Article

A novel reusable ionic liquid chemically bonded fused-silica fiber for headspace solid-phase microextraction/gas chromatography-flame ionization detection of methyl tert-butyl ether in a gasoline sample

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1218, Issue 1, Pages 130-136

Publisher

ELSEVIER
DOI: 10.1016/j.chroma.2010.10.114

Keywords

Ionic liquid; Chemically bonding; Solid-phase microextraction; Methyl tert-butyl ether; Gasoline sample; Gas chromatography

Funding

  1. Research Council of K.N. Toosi University of Technology
  2. Research Council of Research Institute of Petroleum Industry
  3. Research Council of Iranian National Center for Oceanography

Ask authors/readers for more resources

A novel ionic liquid (IL) bonded fused-sil-ica fiber for headspace solid-phase microextraction (HS-SPME)/gas chromatography-flame ionization detection (GC-FID) of methyl tert-butyl ether (MTBE) in a gasoline sample was prepared and used. The new proposed chemically bonded fiber has better thermal stability and durability than its corresponding physically coated fiber. Another advantage is that no spacer was used for the purpose of bonding the IL to the surface of the fused-silica. The latter advantage makes the preparation of these fibers easier with lower cost than those prepared using sol-gel method. The ionic liquid 1-methyl-3-(3-trimethoxysilyl propyl) imidazolium bis(trifluoromethylsulfonyl) imide was synthesized and cross linked to the surface of the fused-silica fiber. Then, the chemically IL-modified fibers were applied to the headspace extraction of MTBE. The chemically IL-modified fibers showed improved thermal stability at temperatures up to 220 degrees C relative to the physically IL-modified fibers (180 degrees C). The chemically bonded IL film on the surface of the fused-silica fiber was durable over 16 headspace extractions without any significant loss of the IL film. The calibration graph was linear in a concentration range of 2-240 mu g L-1 (R-2 = 0.996) with the detection limit of 0.1 mu g L-1 level. The reproducibility (RSD %, n = 6) of the new IL bonded fused-silica fiber (8.9%) was better than the physically coated fiber (12%) suggesting that the proposed chemically IL-modified fiber is more robust than the physically IL-modified fiber. The optimum extraction conditions were the followings: 40 degrees C extraction temperature, 12 min extraction time, 30s desorption time and sample agitation at 200 rpm. (C) 2010 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available