4.6 Article

Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracyclines in milk samples by capillary electrophoresis

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1218, Issue 16, Pages 2196-2202

Publisher

ELSEVIER
DOI: 10.1016/j.chroma.2011.02.046

Keywords

Magnetic solid phase extraction; Phenyl silica adsorbent; Tetracyclines; Milk; Capillary electrophoresis

Funding

  1. CONACyT [61310]
  2. Conselleria de Economia e lndustria. Xunta de Galicia [INCITE09 261 380 PR]
  3. Consejeria de Educacion, Junta de Castilla y Leon [VA023A10-2]

Ask authors/readers for more resources

A magnetic solid phase extraction method coupled to capillary electrophoresis is proposed for the determination of tetracycline, oxytetracycline, chlortetracycline and doxycycline in milk samples. Five different magnetic phenyl silica adsorbents covered with magnetite were synthesized by varying the molar ratio of phenyltrimethylsilane and tetramethylorthosilicate; these adsorbents were evaluated in terms of their pH and degree of hydrophobicity for tetracycline retention. The optimal, selected combination of conditions was a pH of 10.0 and a magnetic sorbent ratio of 4:1; under these conditions, the retention capacity ranged from 99.7% to 101.2% for the four tetracyclines analyzed. The elution conditions and initial sample volume of the proposed extraction method were also optimized, and the best results were obtained with 1 x 10(-3) M acetic acid in methanol as eluent and a 200 ml of sample volume. Under optimal conditions, average recoveries ranged from 94.2% to 99.8% and the limits of detection ranged from 2 to 9 mu g l(-1) for the four tetracyclines. After the proposed method was optimized and validated, 25 milk samples of different brands were analyzed, oxytetracycline residues were detected in five samples, in concentrations ranging from 98 to 213 mu g l(-1). Subsequent analysis of positive samples by SPE-CE and magnetic solid phase extraction-HPLC revealed than no significant differences were found from results obtained by the proposed methodology. Thus, the developed magnetic extraction is a robust pre-concentration technique that can be coupled to other analytical methods for the quantitative determination of tetracyclines. (C) 2011 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available