Separation of oxidized variants of a monoclonal antibody by anion-exchange

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1218, Issue 15, Pages 2091-2097

Publisher

ELSEVIER
DOI: 10.1016/j.chroma.2010.10.107

Keywords

Monoclonal antibodies; Ion-exchange HPLC; Oxidation; Methionyl oxidation in antibodies; Post-translational modifications; Characterization of monoclonal antibodies; Peptide mapping; LC/MS; AEX of antibodies; Anion-exchange of antibodies

Funding

  1. National Institute of Allergy and Infectious Diseases, National Institute of Health
  2. Department of Health and Human Services [HHSN266200600008C]

Ask authors/readers for more resources

Monoclonal antibodies are subject to a variety of degradation mechanisms, therefore orthogonal techniques are required to demonstrate product quality. In this study, the three individual antibodies comprising a multi-antibody drug product, XOMA 3AB were evaluated by both cation-exchange (CEX) and anion-exchange chromatography (AEX). In contrast to CEX analysis which showed only a single, broad peak for the force-oxidized antibodies, AEX analysis of Ab-A (pl = 7.6) revealed two more basic peaks. Ab-B (pl = 6.7) bound but exhibited only a single major peak while Ab-C (pl = 8.6) flowed through. Peptide mapping LC/MS analysis of the isolated Ab-A fractions demonstrated that the basic peaks resulted from oxidation in a complementary determining region (CDR). Differential scanning calorimetry (DSC) analysis of the oxidized Ab-A species showed a decrease in the Fab melting point for the oxidized species consistent with unfolding of the molecule. Greater/lesser surface exposure of ionic residues resulting from a conformational change provides a likely explanation for the dramatic shift in retention behavior for the Ab-A oxidized variants. Peptide mapping analysis of the Ab-B antibody showed, in contrast to Ab-A, no detectable CDR oxidation. Hence, the lack of separation of oxidized variants in Ab-B can be explained by the absence of CDR oxidation and the associated changes in secondary/tertiary structure which were observed for oxidized Ab-A. In summary, anion-exchange HPLC shows potential as an orthogonal analytical technique for assessing product quality of monoclonal antibody therapeutics. In the case of the XOMA 3AB drug product, two of the antibodies bound and one, Ab-A, exhibited separation of CDR oxidized variants. (C) 2010 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available