4.6 Article Proceedings Paper

Screening of drugs in equine plasma using automated on-line solid-phase extraction coupled with liquid chromatography tandem mass spectrometry

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1217, Issue 19, Pages 3289-3296

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2010.01.023

Keywords

On-line SPE; Plasma; Liquid chromatography-tandem mass spectrometry; Horse; Doping control

Ask authors/readers for more resources

A rapid liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed for the simultaneous screening of 19 drugs of different classes in equine plasma using automated on-line solid-phase extraction (SPE) coupled with a triple quadrupole mass spectrometer. Plasma samples were first protein precipitated using acetonitrile. After centrifugation, the supernatant was directly injected into the on-line SPE system and analysed by a triple quadrupole LC-MS-MS in positive electrospray ionisation (+ESI) mode with selected reaction monitoring (SRM) scan function. On-line extraction and chromatographic separation of the targeted drugs were performed using respectively a polymeric extraction column (2 cm L x 2.1 mm ID, 25 mu m particle size) and a reversed-phase C18 LC column (3 cm L x 2.1 mm ID, 3 mu m particle size) with gradient elution to provide fast analysis time. The overall instrument turnaround time was 9.5 min, inclusive of post-run and equilibration time. Plasma samples fortified with 19 targeted drugs including narcotic analgesics, local anaesthetics, antipsychotics, bronchodilators, mucolytics, corticosteroids, sedative and tranquillisers at sub-parts per billion (ppb) to low parts per trillion (ppt) levels could be consistently detected. No significant matrix interference was observed at the expected retention times of the targeted ion transitions. Over 70% of the drugs studied gave detection limits at or below 100 pg/mL, with some detection limits reaching down to 19 pg/mL. The method had been validated for extraction recovery, precision and sensitivity, and a blockage study had also been carried out. This method is used regularly in the authors' laboratory to screen for the presence of targeted drugs in pre-race plasma samples from racehorses. (C) 2010 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available