4.6 Article

On-column liquid-liquid-liquid microextraction coupled with base stacking as a dual preconcentration method for capillary zone electrophoresis

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1216, Issue 15, Pages 3353-3359

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2009.01.070

Keywords

Liquid-liquid-liquid microextraction; Base stacking; Capillary zone electrophoresis; Carbamates; Hydrolysis

Funding

  1. National Science Foundation of China [20675075, 20275035]

Ask authors/readers for more resources

A simple and efficient dual preconcentration method of on-column liquid-liquid-liquid microextraction (LLLME) coupled with base stacking was developed for capillary zone electrophoresis (CZE) in this paper. Four N-methyl carbamates were used as target compounds to evaluate the enrichment means. The carbamates in sample solutions (donor phase) were extracted into a dodecanol phase immobilized on a porous hollow fiber, hydrolyzed and back extracted into 0.20 mu L running buffer (acceptor phase) of 30 mmol/L methylamine hydrochloride (pH 11.6) containing 0.5 mmol/L tetradecyltrimethylammonium bromide inside the hollow fiber, stacked further with 0.5 mol/L NaOH injected at - 10 kV for 60 s. and separated by CZE. Analytical parameters affecting the LLLME, base stacking and CZE were investigated, including sample Solution volume, pH and temperature, extraction time, stirring rate, buffer component, buffer pH, NaOH concentration, stacking time, etc. The enrichment factors of the carbamates were higher than 1100. The relative standard deviation (RSD) of peak height and limits of detection (LODs) were 4.5-5.5% (n = 6) and 2-4 ng/mL (S/N= 3) for standard solutions, respectively. The proposed method was applied to the analysis of vegetable and fruit samples with the RSD less than 6.0% (n = 3) and LODs of 6-10ng/g (S/N=3). The calibration solutions were prepared by diluting the stock solutions with blank sample solutions, and the calibration concentrations ranged from 0.012 to 11.0 mu g/mL (r>0.9951). The analytical results demonstrated that the LLLME coupled with base stacking was a simple, convenient and reliable on-column sample pretreatment method for the analysis of anionic analytes in CZE. (C) 2009 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available