4.6 Article

Determination of phthalates and adipate in bottled water by headspace solid-phase microextraction and gas chromatography/mass spectrometry

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1178, Issue 1-2, Pages 231-238

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2007.11.095

Keywords

headspace; SPME; phthalates; adipate; water

Ask authors/readers for more resources

The performance of three fibres for the headspace solid-phase microextraction (SPME) of di-2-ethylhexyl adipate (DEHA) and eight phthalates in water was investigated systematically under different extraction conditions. Good responses on the 65 mu m polydimethylsiloxane/divinylbenzene (PDMS/DVB) SPME fibre were observed for DEHA and all phthalates. The polydimethylsiloxane (PDMS) SPME fibre had very poor responses for the lighter and slightly polar phthalates, dimethyl phthalate (DMP) and diethyl phthalate (DEP), while the divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibre had very poor responses for the heavier and non-polar adipate and phthalates. The salt (NaCl) was found to increase the partitioning of DMP, DEP, diisobutyl phthalate (DiBP), di-n-butyl phthalate, and benzyl butyl phthalate (BBP) from water into the headspace, while partitioning of heavier adipate and phthalates from water into headspace was suppressed when the concentration of NaCl was above 10%. The automated headspace SPME methods were developed and validated under two different salting conditions (30% NaCl for DMP, DEP and BBP, and 10% for DEHA, DiBP, DBP, di-n-hexyl phthalate (DHP), di-2-ethylhexyl phthalate (DEHP), and di-n-octyl phthalate (DOP)). Linearity with R-2 values better than 0.9949 was observed for DEHA and eight phthalates over the range from 0.1 to 20 mu g L-1. Method detection limits ranged from 0.003 mu g L-1 for DOP to 0.085 mu g L-1 for BBP. Good repeatability was observed for DEHA and most phthalates with relative standard deviation (RSD) values less than 10%. The methods were used to analyse bottled water samples for DEHA and eight phthalates. DMP, DHP, BBP, DEHA and DOP were not detected in any samples. Concentrations of the other phthalates were low (around sub-ppb) except for DBP in the water from a polycarbonate bottle at 1.72 mu g L-1. Crown Copyright (c) 2007 Published by Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available