4.7 Article

Detailed comparison of amyloid PET and CSF biomarkers for identifying early Alzheimer disease

Journal

NEUROLOGY
Volume 85, Issue 14, Pages 1240-1249

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1212/WNL.0000000000001991

Keywords

-

Funding

  1. European Research Council
  2. Swedish Research Council
  3. Strategic Research Area Multi-Park (Multidisciplinary Research in Parkinson's disease) at Lund University
  4. Crafoord Foundation
  5. Swedish Brain Foundation
  6. Skane University Hospital Foundation
  7. Swedish Alzheimer Association
  8. Stiftelsen for Gamla Tjanarinnor
  9. Swedish federal government under the ALF
  10. ADNI (NIH) [U01 AG024904]
  11. DOD ADNI (Department of Defense) [W81XWH-12-2-0012]
  12. National Institute on Aging
  13. National Institute of Biomedical Imaging and Bioengineering
  14. Canadian Institutes of Health Research

Ask authors/readers for more resources

Objective:To compare the diagnostic accuracy of CSF biomarkers and amyloid PET for diagnosing early-stage Alzheimer disease (AD).Methods:From the prospective, longitudinal BioFINDER study, we included 122 healthy elderly and 34 patients with mild cognitive impairment who developed AD dementia within 3 years (MCI-AD). -Amyloid (A) deposition in 9 brain regions was examined with [F-18]-flutemetamol PET. CSF was analyzed with INNOTEST and EUROIMMUN ELISAs. The results were replicated in 146 controls and 64 patients with MCI-AD from the Alzheimer's Disease Neuroimaging Initiative study.Results:The best CSF measures for identifying MCI-AD were A42/total tau (t-tau) and A42/hyperphosphorylated tau (p-tau) (area under the curve [AUC] 0.93-0.94). The best PET measures performed similarly (AUC 0.92-0.93; anterior cingulate, posterior cingulate/precuneus, and global neocortical uptake). CSF A42/t-tau and A42/p-tau performed better than CSF A42 and A42/40 (AUC difference 0.03-0.12, p < 0.05). Using nonoptimized cutoffs, CSF A42/t-tau had the highest accuracy of all CSF/PET biomarkers (sensitivity 97%, specificity 83%). The combination of CSF and PET was not better than using either biomarker separately.Conclusions:Amyloid PET and CSF biomarkers can identify early AD with high accuracy. There were no differences between the best CSF and PET measures and no improvement when combining them. Regional PET measures were not better than assessing the global A deposition. The results were replicated in an independent cohort using another CSF assay and PET tracer. The choice between CSF and amyloid PET biomarkers for identifying early AD can be based on availability, costs, and doctor/patient preferences since both have equally high diagnostic accuracy.Classification of evidence:This study provides Class III evidence that amyloid PET and CSF biomarkers identify early-stage AD equally accurately.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available