4.5 Article

Visualizing dynamic cytoplasmic forces with a compliance-matched FRET sensor

Journal

JOURNAL OF CELL SCIENCE
Volume 124, Issue 2, Pages 261-269

Publisher

COMPANY BIOLOGISTS LTD
DOI: 10.1242/jcs.071928

Keywords

Actinin; Fluorescence energy transfer; Force; FRET; Osmotic pressure; Sensor; Stress

Categories

Funding

  1. US National Institutes of Health

Ask authors/readers for more resources

Mechanical forces are ubiquitous modulators of cell activity but little is known about the mechanical stresses in the cell. Genetically encoded FRET-based force sensors now allow the measurement of local stress in specific host proteins in vivo in real time. For a minimally invasive probe, we designed one with a mechanical compliance matching that of many common cytoskeleton proteins. sstFRET is a cassette composed of Venus and Cerulean linked by a spectrin repeat. The stress sensitivity of the probe was measured in solution using DNA springs to push the donor and acceptor apart with 5-7 pN and this produced large changes in FRET. To measure cytoskeletal stress in vivo we inserted sstFRET into alpha-actinin and expressed it in HEK and BAEC cells. Time-lapse imaging showed the presence of stress gradients in time and space, often uncorrelated with obvious changes in cell shape. The gradients could be rapidly relaxed by thrombin-induced cell contraction associated with inhibition of myosin II. The tension in actinin fluctuated rapidly ( scale of seconds) illustrating a cytoskeleton in dynamic equilibrium. Stress in the cytoskeleton can be driven by macroscopic stresses applied to the cell. Using sstFRET as a tool to measure internal stress, we tested the prediction that osmotic pressure increases cytoskeletal stress. As predicted, hypotonic swelling increased the tension in actinin, confirming the model derived from AFM. Anisotonic stress also produced a novel transient (similar to 2 minutes) decrease in stress upon exposure to a hypotonic challenge, matched by a transient increase with hypertonic stress. This suggests that, at rest, the stress axis of actinin is not parallel to the stress axis of actin and that swelling can reorient actinin to lie more parallel where it can absorb a larger fraction of the total stress. Protein stress sensors are opening new perspectives in cell biology.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available