4.2 Article

Real-World Data on the Lifespan of Implantable Cardioverter-Defibrillators Depending on Manufacturers and the Amount of Ventricular Pacing

Journal

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY
Volume 23, Issue 12, Pages 1336-1342

Publisher

WILEY
DOI: 10.1111/j.1540-8167.2012.02408.x

Keywords

battery longevity; cardiac resynchronization therapy; heart failure; implantable cardioverter-defibrillator; ventricular pacing

Funding

  1. Biotronik
  2. Medtronic
  3. St. Jude Medical
  4. Medtronic Inc.
  5. Sorin

Ask authors/readers for more resources

Real-World Data on the Lifespan of ICDs Introduction: Implantable cardioverter-defibrillator (ICD) longevity is crucial for both patients and public health systems because it determines the number of surgical ICD replacements, which can generally be considered an additional risk factor for complications, and the cost-effectiveness of ICD therapy. Our objective was to obtain insight into the real-world longevities of implantable cardioverter-defibrillators, which quite often differ from those stated in the manufacturers declarations. Methods and Results: On the basis of a prospective database, we analyzed all ICD implantations performed in our hospital from June 1988 to June 2009. We studied 980 patients (follow-up 58 +/- 51 months) with 1,502 ICDs and all respective data until August 2010. We compared the percentage of still operating ICDs at different points in time in relation to manufacturers, types of device (single chamber 623, dual chamber 588, cardiac resynchronization therapy ICDs [CRT-D] 291), and amount of right ventricular pacing (VP). We found distinct differences between the mean lifespans of ICDs of different manufacturers (Biotronik 4.3 years, Sorin 4.5 years, Guidant/Boston Scientific 4.7 years, St. Jude Medical 5 years, Medtronic 5.8 years). CRT-D devices (hazard ratio [HR] 1.778, P = 0.0005) were associated with an elevated annual relative risk for device replacement while a decrease in the proportion of VP (HR 0.934 for each 10% decrease in VP, P < 0.0001) and Medtronic ICDs were associated with a reduced risk of device replacement (HR 0.544, P < 0.0001). Conclusion: CRT-Ds and an elevated percentage of VP are associated with a significantly elevated risk for device replacement, while Medtronic ICDs showed the longest lifespans. (J Cardiovasc Electrophysiol, Vol. 23, pp. 1336-1342, December 2012)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available