4.5 Article

Quantitative evaluation of high-density diffuse optical tomography: in vivo resolution and mapping performance

Journal

JOURNAL OF BIOMEDICAL OPTICS
Volume 15, Issue 2, Pages -

Publisher

SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS
DOI: 10.1117/1.3368999

Keywords

medical imaging; biomedical optics; image quality; imaging systems; diffusion; diffuse optical tomography; optical neuroimaging

Funding

  1. NIH [R21-HD057512, R21-EB007924, R01-EB009233, T90-DA022871]
  2. EUNICE KENNEDY SHRIVER NATIONAL INSTITUTE OF CHILD HEALTH &HUMAN DEVELOPMENT [R21HD057512] Funding Source: NIH RePORTER
  3. NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING [R01EB009233, R21EB007924] Funding Source: NIH RePORTER
  4. NATIONAL INSTITUTE ON DRUG ABUSE [T90DA022871] Funding Source: NIH RePORTER

Ask authors/readers for more resources

Despite the unique brain imaging capabilities and advantages of functional near-infrared spectroscopy (fNIRS), including portability and comprehensive hemodynamic measurement, widespread acceptance in the neuroimaging community has been hampered by low spatial resolution and image localization errors. While recent technical developments such as high-density diffuse optical tomography (HD-DOT) have, in principle, been shown to have superior in silica image quality, the majority of optical imaging studies are still conducted with sparse fNIRS arrays, perhaps partially because the performance increases of HD-DOT appear incremental. Without a quantitative comparative analysis between HD-DOT and fNIRS, using both simulation and in vivo neuroimaging, the implications of the new HD-DOT technology have been difficult to judge. We present a quantitative comparison of HD-DOT and two commonly used fNIRS geometries using (1) standard metrics of image quality, (2) simulated brain mapping tasks, and (3) in vivo visual cortex mapping results in adult humans. The results show that better resolution and lower positional errors are achieved with HD-DOT and that these improvements provide a substantial advancement in neuroimaging capability. In particular, we demonstrate that HD-DOT enables detailed phase-encoded retinotopic mapping, while sparse arrays are limited to imaging individual block-design visual stimuli. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3368999]

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available