We validate a simple method for determining the confidence intervals on fitted parameters derived from modeling optical reflectance spectroscopy measurements using synthetic datasets. The method estimates the parameter confidence intervals as the square roots of the diagonal elements of the covariance matrix, obtained by multiplying the inverse of the second derivative matrix of chi(2) with respect to its free parameters by chi(2)/v, with v the number of degrees of freedom. We show that this method yields correct confidence intervals as long as the model used to describe the data is correct. Imperfections in the fitting model introduces a bias in the fitted parameters that greatly exceeds the estimated confidence intervals. We investigate the use of various methods to identify and subsequently minimize the bias in the fitted parameters associated with incorrect modeling. (C) 2008 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.2982523]

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available