Application of motion analysis system in pre-impact fall detection

Journal

JOURNAL OF BIOMECHANICS
Volume 41, Issue 10, Pages 2297-2304

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.jbiomech.2008.03.042

Keywords

motion analysis system; Vicon; faint fall; syncope; elderly

Ask authors/readers for more resources

The purpose of this study is to investigate unique features of body segments in fall and activities of daily living (ADL) to make automatic detection of fall in its descending phase before the impact. Thus, fall-related injuries can be prevented or reduced by deploying feedback systems before the impact. In this study, the authors propose the following hypothesis: (1) thigh segment normally does not go beyond certain threshold angle to forward and sideways directions in ADL and (2) even if it does, the angular characteristics Measured at torso and thigh differ from one another in ADL whereas in the case of fall, they become congruent. These two factors call be used to distinguish fall from ADL in its inception. Vicon 3-D motion analysis system Was used in this Study. High level of correlation between thigh and torso segments (corr > 0.99) was found for fall activities and low correlation coefficients (mean corr for lateral movements is 0.2338 and for sagittal movements is -0.665) were observed in ADL. By applying the hypothesis, all simulated falls could be detected with no false alarms and around 700 ins lead-time before the impact was achieved in pre-impact fall detection. It is the longest lead-time obtained so far in pre-impact fall detection. (C) 2008 Published by Elsevier Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available