4.2 Article

On the Importance of Modeling Stent Procedure for Predicting Arterial Mechanics

Related references

Note: Only part of the references are listed.
Article Computer Science, Interdisciplinary Applications

Assessment of mechanical integrity for drug-eluting renal stent with micro-sized drug reservoirs

Hao-Ming Hsiao et al.

COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING (2013)

Article Medicine, Research & Experimental

Increased artery wall stress post-stenting leads to greater intimal thickening

Lucas H. Timmins et al.

LABORATORY INVESTIGATION (2011)

Article Cardiac & Cardiovascular Systems

Virtual bench testing of new generation coronary stents

Peter Mortier et al.

EUROINTERVENTION (2011)

Article Engineering, Biomedical

Surgical stent planning: simulation parameter study for models based on DICOM standards

S. Scherer et al.

INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY (2011)

Article Engineering, Biomedical

The Relation Between the Arterial Stress and Restenosis Rate After Coronary Stenting

Linxia Gu et al.

JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME (2010)

Review Engineering, Biomedical

Materials for metallic stents

Takao Hanawa

JOURNAL OF ARTIFICIAL ORGANS (2009)

Article Computer Science, Interdisciplinary Applications

Determination of the influence of stent strut thickness using the finite element method: implications for vascular injury and in-stent restenosis

Houman Zahedmanesh et al.

MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING (2009)

Article Engineering, Biomedical

Simulation of stent deployment in a realistic human coronary artery

Frank J. H. Gijsen et al.

BIOMEDICAL ENGINEERING ONLINE (2008)

Article Biophysics

Numerical study of the uniformity of balloon-expandable stent deployment

P. Mortier et al.

JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME (2008)

Article Biophysics

Realistic finite element-based stent design: The impact of balloon folding

Matthieu De Beule et al.

JOURNAL OF BIOMECHANICS (2008)

Article Engineering, Chemical

Macroscopic friction coefficient measurements on living endothelial cells

Alison C. Dunn et al.

TRIBOLOGY LETTERS (2007)

Article Cardiac & Cardiovascular Systems

Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery

DK Liang et al.

INTERNATIONAL JOURNAL OF CARDIOLOGY (2005)

Article Biophysics

Cardiovascular stent design and vessel stresses: a finite element analysis

C Lally et al.

JOURNAL OF BIOMECHANICS (2005)

Article Biophysics

Changes in the mechanical environment of stenotic arteries during interaction with stents: Computational assessment of parametric stent designs

G Holzapfel et al.

JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME (2005)

Article Biophysics

Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall

Francesco Migliavacca et al.

BIOMECHANICS AND MODELING IN MECHANOBIOLOGY (2004)

Article Biophysics

Mechanical behaviour modelling of balloon-expandable stents

C Dumoulin et al.

JOURNAL OF BIOMECHANICS (2000)