4.3 Article

Evaluation of the New Version of the Laser-Optical Disdrometer, OTT Parsivel2

Journal

JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY
Volume 31, Issue 6, Pages 1276-1288

Publisher

AMER METEOROLOGICAL SOC
DOI: 10.1175/JTECH-D-13-00174.1

Keywords

-

Funding

  1. NASA's Global Precipitation Measurement mission under Arthur Hou of NASA's Goddard Space Flight Center, project scientist
  2. NASA's Global Precipitation Measurement mission under Precipitation Measurement Mission (PMM) [NNX07AF45G, NNX10AJ12G]
  3. NASA's Global Precipitation Measurement mission under Ramesh Kakar of NASA headquarters, program scientist
  4. NASA [132163, NNX10AJ12G] Funding Source: Federal RePORTER

Ask authors/readers for more resources

A comparative study of raindrop size distribution measurements has been conducted at NASA's Goddard Space Flight Center where the focus was to evaluate the performance of the upgraded laser-optical OTT Particle Size Velocity (Parsivel(2); P2) disdrometer. The experimental setup included a collocated pair of tipping-bucket rain gauges, OTT Parsivel (P1) and P2 disdrometers, and Joss-Waldvogel (JW) disdrometers. Excellent agreement between the two collocated rain gauges enabled their use as a relative reference for event rain totals. A comparison of event total showed that the P2 had a 6% absolute bias with respect to the reference gauges, considerably lower than the P1 and JW disdrometers. Good agreement was also evident between the JW and P2 in hourly raindrop spectra for drop diameters between 0.5 and 4 mm. The P2 drop concentrations mostly increased toward small sizes, and the peak concentrations were mostly observed in the first three measurable size bins. The P1, on the other hand, underestimated small drops and overestimated the large drops, particularly in heavy rain rates. From the analysis performed, it appears that the P2 is an improvement over the P1 model for both drop size and rainfall measurements. P2 mean fall velocities follow accepted terminal fall speed relationships at drop sizes less than 1 mm. As a caveat, the P2 had approximately 1 m s(-1) slower mean fall speed with respect to the terminal fall speed near 1 mm, and the difference between the mean measured and terminal fall speeds reduced with increasing drop size. This caveat was recognized as a software bug by the manufacturer and is currently being investigated.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available