4.5 Article

Effect of initial gas bubble composition on detection of inducible intrapulmonary arteriovenous shunt during exercise in normoxia, hypoxia, or hyperoxia

Journal

JOURNAL OF APPLIED PHYSIOLOGY
Volume 110, Issue 1, Pages 35-45

Publisher

AMER PHYSIOLOGICAL SOC
DOI: 10.1152/japplphysiol.00145.2010

Keywords

saline contrast echocardiography; gas bubble dynamics; microbubbles in blood; ultrasound contrast agents

Funding

  1. University of Oregon
  2. University of Oregon, Oregon Health and Science University Medical Research Foundation [0820]
  3. American Physiological Society

Ask authors/readers for more resources

Elliott JE, Choi Y, Laurie SS, Yang X, Gladstone IM, Lovering AT. Effect of initial gas bubble composition on detection of inducible intrapulmonary arteriovenous shunt during exercise in normoxia, hypoxia, or hyperoxia. J Appl Physiol 110: 35-45, 2011. First published September 16, 2010; doi:10.1152/japplphysiol.00145.2010.-Concern has been raised that altering the fraction of inspired O-2 (FIO2) could accelerate or decelerate microbubble dissolution time within the pulmonary vasculature and thereby invalidate the ability of saline contrast echocardiography to detect intrapulmonary arteriovenous shunt in subjects breathing either a low or a high FIO2. The present study determined whether the gaseous component used for saline contrast echocardiography affects the detection of exercise-induced intrapulmonary arteriovenous shunt under varying FIO2. Twelve healthy human subjects (6 men, 6 women) performed three 11-min bouts of cycle ergometer exercise at 60% peak O-2 consumption (VO2peak) in normoxia, hypoxia (FIO2 = 0.14), and hyperoxia (FIO2 = 1.0). Five different gases were used to create saline contrast microbubbles by two separate methods and were injected intravenously in the following order at 2-min intervals: room air, 100% N-2, 100% O-2, 100% CO2, and 100% He. Breathing hyperoxia prevented exercise-induced intrapulmonary arteriovenous shunt, whereas breathing hypoxia and normoxia resulted in a significant level of exercise-induced intrapulmonary arteriovenous shunt. During exercise, for any FIO2 there was no significant difference in bubble score when the different microbubble gas compositions made with either method were used. The present results support our previous work using saline contrast echocardiography and validate the use of room air as an acceptable gaseous component for use with saline contrast echocardiography to detect intrapulmonary arteriovenous shunt during exercise or at rest with subjects breathing any FIO2. These results suggest that in vivo gas bubbles are less susceptible to changes in the ambient external environment than previously suspected.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available